UHMW-PE Panel Fenders

Features

DockGuard’s panel Fenders are UHMW-PE 1000 Grade manufactured and machined in sizes to suit the panel. They fixed to the panel generally with M16 St St studs that are welded to the skin of the panel. The minimum wear allowance on the PE is 12mm

UHMW-PE Panel Fenders are supplied pre- drilled for easy installation and chamfered to avoid snagging. The PE normally arrives on site pre fitted to the steel panel. They are available in a full range of colours – either to suit the aesthetics of the installation, to match corporate colour schemes or in high visibility colours for added safety and easier quay/jetty identification.

Key Benefits

UHMW-PE Panel fenders provide the benefits of higher wear resistance (even greater than steel) and lower maintenance; as they do not split or rot and are fully resistant to infestation from marine borers. The low friction coefficient and high abrasion resistance of UHMW-PE provides an ultra smooth surface for the vessel to slide easily along the face of the fender.

UHMW-PE Panel Fender Specification

<< swipe table content >>

ABTDEF MaxG MaxH MaxJWeight
5005003010M165005005097
5005004010M16500500501310
5005005010M16500500751612
5005006010M16500500751914
5005007010M245005001002217
50010003010M1650050050914
50010004010M16500500501319
50010005010M20500500751624
50010006010M20500500751929
50010007010M245005001002234
100010004010M16500500501338
100010005010M16500500751648
100010006010M20500500751958
100010007010M245005001002267
100015004010M16500500501358
100015005010M16500500751672
150015004015M16500500501386
150015005015M165005007516108
120020004015M16500500501392
120020005015M165005007516115
150020004015M165005005013115
150020005015M165005007516144

All dimensions in mm. All weights in Kgs per 1000mm length.

UHMW PE Fender Properties

<< swipe table content >>

Test MethodTesting StandardTypical ValueUnit
DensityDIN 53479 / ASTM D 7920.93-0.95g/cm³
Molecular WeightViscosimetric~4,000,000g/mol
Dynamic FrictionDIN 53375 / ASTM D 1894≤0.15__
Yield StrengthISO 527 / ASTM D 638≥17 / ≥20MPa
Tensile BreakASTM D 638≥40MPa
Elongation at BreakISO 527 / ASTM D 638≥50 / ≥350%
Flexural ModulusASTM D 790B≥800MPa
Shore HardnessISO 86860__
Single-V notched ImpactISO 868 / ASTM 256A≥130 / No breakKj/m²
Abrasion IndexSand Slurry (steel=100)10-15__
Operating Temperature__-80 to +80°C
Thermal ExpansionDIN 52328 / ASTM D 696~2x10ˉ4Kˉ¹
Print Friendly, PDF & EmailDownload Datasheet